This tender in no longer available.

Tender description

Medical supplies for interventional procedures-introducers, wires, catheters and other medical supplies.



Procedure

Type of contest
Open
Date
2020-08-10
Languages in which projects or requests to participate may be drawn up
MK
Conditions for opening of tenders

2020-08-10

13:00

The procurement is covered by the Government Procurement Agreement
No
Local time
13:00

Complementary information

Review body

University Clinic of Cardiology

Skopje

This is a recurrent procurement
Yes
Date of dispatch of this notice
2020-07-09 Main CPV code 33000000

Bidding information

Bidding deadline

10 Aug 2020

0 days remaining

Total estimated value

MKD 57.9 million

Locations

North Macedonia, Skopje

LOTS ASSOCIATED WITH THIS TENDER

Introducer (Set) for a Femoral Arterial Approach Consisting of Hydrophilic Heath, 10 cm Long and Diameter Range of Four to Nine French, with an Anti-folding Layer, with Hemostatic Valve, a Dilator, a 45 cm

Value

MKD Not specified

Introducer (Set) for a Femoral Arterial Approach Consisting of Hydrophilic Heath, 10 cm Long and Diameter Range of Four to Nine French, with an Anti-folding Layer, with Hemostatic Valve, a Dilator, a 45 cm Introducer (Set) for a femoral arterial approach consisting of hydrophilic sheath, 10 cm long and diameter range of four to nine French, with an anti-folding layer, with hemostatic valve, a dilator, a 45 cm.

Introducer (Set) for radial arterial access consisting of a hydrophilic introducer (sheath) with a diameter of 4 to 6 French with an anti-folding layer and with a length of 10 to 25 cm, dilator, with

Value

MKD Not specified

Introducer (Set) for radial arterial access consisting of a hydrophilic introducer (sheath) with a diameter of 4 to 6 French with an anti-folding layer and with a length of 10 to 25 cm, dilator, with Introducer (Set) for radial arterial access consisting of a hydrophilic introducer (sheath) with a diameter of 4 to 6 French with an anti-folding layer and with a length of 10 to 25 cm, dilator, with hemostatic valve, plastic wire with a length of 45 to 80 cm and thickness of 0.025", 20G puncture cannula, 32 mm in length, 2.5ml syringe

Guiding (sheath) introducer, hydrophilic for peripheral interventions with a length of 45 to 90 cm, straight or curved at the tip, with an outer diameter of 5 to 8 French (inner diameter at least 2.2

Value

MKD Not specified

Guiding (sheath) introducer, hydrophilic for peripheral interventions with a length of 45 to 90 cm, straight or curved at the tip, with an outer diameter of 5 to 8 French (inner diameter at least 2.2 Guiding (sheath) introducer, hydrophilic for peripheral interventions with a length of 45 to 90 cm, straight or curved at the tip, with an outer diameter of 5 to 8 French (inner diameter at least 2.2 mm for 6F), with a steel anti-folding support spiral and rtg visible marker on tip, inner PTFE layer and outer layer of nylon, coated with hydrophilic layer of 5 and 35 cm at distal end, with Tuohy-Borst Sidearm or Check-flo valve, Compatible with 0.038 " inch wire.

Guiding (sheath) ntroducer, hydrophilic and flexible for peripheral interventions, with a length of up to 110 cm, straight or curved at the tip, with an outer diameter of 6F with an inner diameter of

Value

MKD Not specified

Guiding (sheath) ntroducer, hydrophilic and flexible for peripheral interventions, with a length of up to 110 cm, straight or curved at the tip, with an outer diameter of 6F with an inner diameter of Guiding (sheath) ntroducer, hydrophilic and flexible for peripheral interventions, with a length of up to 110 cm, straight or curved at the tip, with an outer diameter of 6F with an inner diameter of at least 2.2 mm with a steel anti-folding support spiral and RTG visible marker on tip, PTFE inner layer, with Tuohy-Borst Sidearm valve, with the possibility of a carotid set with a carotid catheter. Compatible with 0.035 inch wire.

Guiding (sheath) introducer, hydrophobic for peripheral interventions with a length of 45 to 90 cm, straight or curved at the tip, with an outer diameter of 4 to 6 French (inner diameter at least 1.61

Value

MKD Not specified

Guiding (sheath) introducer, hydrophobic for peripheral interventions with a length of 45 to 90 cm, straight or curved at the tip, with an outer diameter of 4 to 6 French (inner diameter at least 1.61 Guiding (sheath) introducer, hydrophobic for peripheral interventions with a length of 45 to 90 cm, straight or curved at the tip, with an outer diameter of 4 to 6 French (inner diameter at least 1.61 mm for 4F, 1.91 mm for 5F and 2.25 mm for 6F), with a steel anti-folding support spiral and outer layer coated with hydrophobic material in length of 30 cm at distal end, compatible with 0.035" inch wire

Introducer (Set) for a femoral arterial approach consisting of solid introducer (sheath) with length of 30 to 35 cm and a diameter range of 12 to 20 French with a hemostatic valve, a dilator with a gr

Value

MKD Not specified

Introducer (Set) for a femoral arterial approach consisting of solid introducer (sheath) with length of 30 to 35 cm and a diameter range of 12 to 20 French with a hemostatic valve, a dilator with a gr Introducer (Set) for a femoral arterial approach consisting of solid introducer (sheath) with length of 30 to 35 cm and a diameter range of 12 to 20 French with a hemostatic valve, a dilator with a gradually conical diameter, for large diameter femoral puncture (TAVI, TEVAR EVAR)

Steel guiding wire for establushing initial access and catheters, with standard support stiffness, atraumatic flexible tip with spiral wire design, J-shaped tip style or Rosen and Benton shape, 0.032

Value

MKD Not specified

Steel guiding wire for establushing initial access and catheters, with standard support stiffness, atraumatic flexible tip with spiral wire design, J-shaped tip style or Rosen and Benton shape, 0.032 Steel guiding wire for establushing initial access and catheters, with standard support stiffness, atraumatic flexible tip with spiral wire design, J-shaped tip style or Rosen and Benton shape, 0.032 to 0.038 thick and length range from 180cm to at least 260cm, with steel core and PTFE coating

Steel guiding wire for Lunderquist support, Extra-stiff design of extremely strong support for installing and changing catheters through highly tortuous or calcified arteries, support stronger than am

Value

MKD Not specified

Steel guiding wire for Lunderquist support, Extra-stiff design of extremely strong support for installing and changing catheters through highly tortuous or calcified arteries, support stronger than am Steel guiding wire for Lunderquist support, Extra-stiff design of extremely strong support for installing and changing catheters through highly tortuous or calcified arteries, support stronger than amplataz ultra stiff design, made of steel and with flopy atraumatic tip with spiral design, curved or straight. Tip 4-7 cm fluoroscopically visible, diameter of 0.035 inches and length of at least 260 cm

Guiding wire from nitinol, hydrophilic, for installing catheters through peripheral arteries with standard or solid support, (stiff type) conically thinned tip with straight, angular or curved style.

Value

MKD Not specified

Guiding wire from nitinol, hydrophilic, for installing catheters through peripheral arteries with standard or solid support, (stiff type) conically thinned tip with straight, angular or curved style. Guiding wire from nitinol, hydrophilic, for installing catheters through peripheral arteries with standard or solid support, (stiff type) conically thinned tip with straight, angular or curved style. Covered with a fluoroscopically visible polyurethane with a tungsten and hydrophilic layer along its entire length. Diameter from 0.018 to 0.035 inches and length 180 to 260 cm

Guiding wire, hydrophilic, with hybrid design for peripheral interventions. Made of a nitinol core with a conical tip with a 25 cm polyurethane coating, RTG visible marker, and the rest of the PTFE sp

Value

MKD Not specified

Guiding wire, hydrophilic, with hybrid design for peripheral interventions. Made of a nitinol core with a conical tip with a 25 cm polyurethane coating, RTG visible marker, and the rest of the PTFE sp Guiding wire, hydrophilic, with hybrid design for peripheral interventions. Made of a nitinol core with a conical tip with a 25 cm polyurethane coating, RTG visible marker, and the rest of the PTFE spiral coating with a hydrophilic layer. Tip design with 1cm flexibility for 0.014 and 0.018 inch diameters and 5cm for 0.035 inch diameter. Length from 180 to 300 cm.

Guiding wire for peripheral interventions, below the knee, with hybrid design, steel core and nitinol tip, suitable for shaping, hydrophilic coating of the polymer that is at least 3 cm visible, the t

Value

MKD Not specified

Guiding wire for peripheral interventions, below the knee, with hybrid design, steel core and nitinol tip, suitable for shaping, hydrophilic coating of the polymer that is at least 3 cm visible, the t Guiding wire for peripheral interventions, below the knee, with hybrid design, steel core and nitinol tip, suitable for shaping, hydrophilic coating of the polymer that is at least 3 cm visible, the tip weighing from 2.8 to 3.5 g, diameter 0.014 inches and a length of 190 to 300 cm.

Guiding wire for peripheral interventions in chronic occlusions, with single core design, for peripheral interventions with penetrating technique, diameter of 0.014 and 0.018 inches, and conical tip o

Value

MKD Not specified

Guiding wire for peripheral interventions in chronic occlusions, with single core design, for peripheral interventions with penetrating technique, diameter of 0.014 and 0.018 inches, and conical tip o Guiding wire for peripheral interventions in chronic occlusions, with single core design, for peripheral interventions with penetrating technique, diameter of 0.014 and 0.018 inches, and conical tip of 0.008 to 0.013 inches, at least 15 cm RTG visibility of the tip, tip weight of 20, 30 and 40 gr.

Steel guiding wire for TAVI procedure of 0.035 inches (with pre-formed loop shape in three sizes, from 29 to 50 mm on the distal 15 cm of the tip) during the TAVI procedure. The wire with a total leng

Value

MKD Not specified

Steel guiding wire for TAVI procedure of 0.035 inches (with pre-formed loop shape in three sizes, from 29 to 50 mm on the distal 15 cm of the tip) during the TAVI procedure. The wire with a total leng Steel guiding wire for TAVI procedure of 0.035 inches (with pre-formed loop shape in three sizes, from 29 to 50 mm on the distal 15 cm of the tip) during the TAVI procedure. The wire with a total length of at least 260cm, designed for stable atraumatic wire placement in the left ventricle during a TAVI procedure. Wire stiffness less than Amplatz ultra stiff wire.

Extra stiff guiding wire, 0.035 inch, for TAVI procedure (with formed distal loop of at least 30 mm in diameter). Wire with a total length of at least 260cm, designed for stable atraumatic placement o

Value

MKD Not specified

Extra stiff guiding wire, 0.035 inch, for TAVI procedure (with formed distal loop of at least 30 mm in diameter). Wire with a total length of at least 260cm, designed for stable atraumatic placement o Extra stiff guiding wire, 0.035 inch, for TAVI procedure (with formed distal loop of at least 30 mm in diameter). Wire with a total length of at least 260cm, designed for stable atraumatic placement of the wire in the left ventricle during a TAVI procedure. Wire stiffness more than Amplatz ultra stiff wire

Guiding wire for coronary interventions made of nitinol alloy, designed for routine interventions, with a diameter of 0.014 inches, length from 190 to 300 cm, flexible tip from 0.6 to 0.8 g in weight

Value

MKD Not specified

Guiding wire for coronary interventions made of nitinol alloy, designed for routine interventions, with a diameter of 0.014 inches, length from 190 to 300 cm, flexible tip from 0.6 to 0.8 g in weight Guiding wire for coronary interventions made of nitinol alloy, designed for routine interventions, with a diameter of 0.014 inches, length from 190 to 300 cm, flexible tip from 0.6 to 0.8 g in weight with a spiral part of 3 cm RTG visible, with tip style in the form of a shaping tape, coil at the tip, and a predefined straight or curved shape of the tip. The wire can be with hydrophilic or hydrophobic coating on tip.

Guiding wire for coronary interventions made of steel alloy, hydrophilic with polymer sleeve 20-30 cm from the tip, for tortuous arteries, with dimension 0.014", from 190 cm to 300 cm length span with

Value

MKD Not specified

Guiding wire for coronary interventions made of steel alloy, hydrophilic with polymer sleeve 20-30 cm from the tip, for tortuous arteries, with dimension 0.014", from 190 cm to 300 cm length span with Guiding wire for coronary interventions made of steel alloy, hydrophilic with polymer sleeve 20-30 cm from the tip, for tortuous arteries, with dimension 0.014", from 190 cm to 300 cm length span with different degree of support at the tip (LS, MS, Extra support) different weight at the tip, from 0.8 to 1.5 g. Tip style - core-to-tip, in one whole, for better control, RTG visibility of the tip of 3cm,

Guiding wire for coronary interventions made of nitinol alloy, for enhanced intervention support, with a diameter of 0.014 inches, length from 190 to 300 cm, flexible tip of 0.8 g in weight with a spi

Value

MKD Not specified

Guiding wire for coronary interventions made of nitinol alloy, for enhanced intervention support, with a diameter of 0.014 inches, length from 190 to 300 cm, flexible tip of 0.8 g in weight with a spi Guiding wire for coronary interventions made of nitinol alloy, for enhanced intervention support, with a diameter of 0.014 inches, length from 190 to 300 cm, flexible tip of 0.8 g in weight with a spiral part of 4.5 cm RTG visible, with tip style in the form of a shaping tape, with hydrophilic coating, predefined straight or curved shape of the tip

Guiding wire for coronary interventions made of steel alloy, with flexible and gentle floppy tip in interventions, with dimension 0.014", length from 190 cm to 300 cm, flexible tip from 0.4 to 0.6 g w

Value

MKD Not specified

Guiding wire for coronary interventions made of steel alloy, with flexible and gentle floppy tip in interventions, with dimension 0.014", length from 190 cm to 300 cm, flexible tip from 0.4 to 0.6 g w Guiding wire for coronary interventions made of steel alloy, with flexible and gentle floppy tip in interventions, with dimension 0.014", length from 190 cm to 300 cm, flexible tip from 0.4 to 0.6 g weight with a spiral part of 2 cm RTG visible, with tip style in the form of coils and a shaping tape, with hydrophilic or hydrophobic coating.

Guiding wire for coronary interventions made of steel alloy, for extra support during interventions, 20 grams at 70 mm from the tip, with diameter 0.014 inches, length 190 to 300 cm, flexible tip with

Value

MKD Not specified

Guiding wire for coronary interventions made of steel alloy, for extra support during interventions, 20 grams at 70 mm from the tip, with diameter 0.014 inches, length 190 to 300 cm, flexible tip with Guiding wire for coronary interventions made of steel alloy, for extra support during interventions, 20 grams at 70 mm from the tip, with diameter 0.014 inches, length 190 to 300 cm, flexible tip with 0.9 g weight, length 3 cm RTG visible predefined straight or curved shape of the tip. Tip style - core-to-tip, in one whole, for better control, and the wire with hydrophobic coating

Guiding wire for interventions in highly torturous and stenotic coronary arteries, made of steel alloy, for extra support during interventions, with a diameter of 0.014 inches, length from 182 to 300

Value

MKD Not specified

Guiding wire for interventions in highly torturous and stenotic coronary arteries, made of steel alloy, for extra support during interventions, with a diameter of 0.014 inches, length from 182 to 300 Guiding wire for interventions in highly torturous and stenotic coronary arteries, made of steel alloy, for extra support during interventions, with a diameter of 0.014 inches, length from 182 to 300 cm, flexible tip of 2.0 g in weight, hydrophilic with polymer sleeve in length of 35 cm RTG visible. Tip style - core-to-tip, in one whole, for better control,

Guiding wire for coronary interventions in chronic occlusions, made of steel alloy, 0.014 inch in diameter, length 190 to 300 cm, hydrophilic with hybrid coating with polymer sleeve at least 20 cm and

Value

MKD Not specified

Guiding wire for coronary interventions in chronic occlusions, made of steel alloy, 0.014 inch in diameter, length 190 to 300 cm, hydrophilic with hybrid coating with polymer sleeve at least 20 cm and Guiding wire for coronary interventions in chronic occlusions, made of steel alloy, 0.014 inch in diameter, length 190 to 300 cm, hydrophilic with hybrid coating with polymer sleeve at least 20 cm and no polymer at the tip, penetration tip of 4.7 to 14 g in weight, 3 cm long RTG visible, predefined straight or curved shaped tip. Tip style - core-to-tip, in one whole, for better control, certain models with conical narrowing at the tip.

Guiding wire for coronary interventions in chronic occlusions, made of steel alloy, 0.010 inches in diameter, length 190 to 300 cm, hydrophilic, at the tip penetrating tip conically narrowed from 4.7

Value

MKD Not specified

Guiding wire for coronary interventions in chronic occlusions, made of steel alloy, 0.010 inches in diameter, length 190 to 300 cm, hydrophilic, at the tip penetrating tip conically narrowed from 4.7 Guiding wire for coronary interventions in chronic occlusions, made of steel alloy, 0.010 inches in diameter, length 190 to 300 cm, hydrophilic, at the tip penetrating tip conically narrowed from 4.7 to 9 g weight, length 3 cm RTG visible, predefined straight or curved shaped tip. Tip style - core-to-tip, in one whole, for better control, for penetrating technique of passing through the occlusion.

Guiding wire for complex coronary interventions for overcoming long complex lesions and total occlusion with microchannel technique, made of steel alloy core with one-piece core wire and coating, with

Value

MKD Not specified

Guiding wire for complex coronary interventions for overcoming long complex lesions and total occlusion with microchannel technique, made of steel alloy core with one-piece core wire and coating, with Guiding wire for complex coronary interventions for overcoming long complex lesions and total occlusion with microchannel technique, made of steel alloy core with one-piece core wire and coating, with conical tip "tapered tip" 0.014"/0.010"(0.36mm/0.23mm) hydrophilic coated tip with polymer 16 cm RTG visible and "tip load" 0.6-1.0 g, from 190 cm to 300cm length range

Guiding wire for coronary interventions for access to lateral branches in highly torturous and stenotic coronary arteries, made of steel allow in one whole, for better control, 0.014 inch in diameter,

Value

MKD Not specified

Guiding wire for coronary interventions for access to lateral branches in highly torturous and stenotic coronary arteries, made of steel allow in one whole, for better control, 0.014 inch in diameter, Guiding wire for coronary interventions for access to lateral branches in highly torturous and stenotic coronary arteries, made of steel allow in one whole, for better control, 0.014 inch in diameter, 180 to 300 cm in length, flexible tip from 0.5 to 1 g weight, hydrophilic coating in length from 18 to 40 cm RTG visible in the first three cm,

Guiding wire for complex coronary interventions for overcoming long complex lesions and total occlusion with penetration technique, made of steel alloy core with one-piece core wire, with conical tip

Value

MKD Not specified

Guiding wire for complex coronary interventions for overcoming long complex lesions and total occlusion with penetration technique, made of steel alloy core with one-piece core wire, with conical tip Guiding wire for complex coronary interventions for overcoming long complex lesions and total occlusion with penetration technique, made of steel alloy core with one-piece core wire, with conical tip "tapered tip" 0.010"/0.012", hydrophilic coating, tip of 40 cm, 15 cm RTG visible and "tip load" 1,7-4,5 g, length 190 cm, given a specific shape of the tip, which is a penetrating uncoated cone

Diagnostic angiographic catheters, with multiple shapes and purposes (coronary left and right, MP and Pigtail), 4 to 6 French in diameter, from hydrophilic nylon, with graded, variable mesh support, a

Value

MKD Not specified

Diagnostic angiographic catheters, with multiple shapes and purposes (coronary left and right, MP and Pigtail), 4 to 6 French in diameter, from hydrophilic nylon, with graded, variable mesh support, a Diagnostic angiographic catheters, with multiple shapes and purposes (coronary left and right, MP and Pigtail), 4 to 6 French in diameter, from hydrophilic nylon, with graded, variable mesh support, and lengths up to 110 cm for some shapes and blood vessels, with high quality and low degree of radial spasm when passing through the artery. Internal diameter for 5 French of 0.047 inches. Compatible with 0.038" guiding wires.

Guiding-catheters for coronary interventions (diameter 5F, 6F, 7F, 8F) left, right, different curves, RTG visibility and RTG marker on the tip, atraumatic tip, large inner lumen of at least 0.071" for

Value

MKD Not specified

Guiding-catheters for coronary interventions (diameter 5F, 6F, 7F, 8F) left, right, different curves, RTG visibility and RTG marker on the tip, atraumatic tip, large inner lumen of at least 0.071" for Guiding-catheters for coronary interventions (diameter 5F, 6F, 7F, 8F) left, right, different curves, RTG visibility and RTG marker on the tip, atraumatic tip, large inner lumen of at least 0.071" for 6F, compatible for two-balloon kissing technique, catheter length of at least 100 cm (with the possibility of making more curves as needed). Compatible with 0.038" guiding wires.

Diagnostic catheters for access to cervical arteries and cerebral access with different SIMMONS curves (1,2,3) diameter of 4 to 6 French, internal diameter for 5 French of 0.047 inches, from hydrophil

Value

MKD Not specified

Diagnostic catheters for access to cervical arteries and cerebral access with different SIMMONS curves (1,2,3) diameter of 4 to 6 French, internal diameter for 5 French of 0.047 inches, from hydrophil Diagnostic catheters for access to cervical arteries and cerebral access with different SIMMONS curves (1,2,3) diameter of 4 to 6 French, internal diameter for 5 French of 0.047 inches, from hydrophilic nylon, length range of 100 cm to 125 cm with double mesh wire support. Compatible with 0.038" guiding wires.

Guiding catheter Extension, "rapid exchange", compatible with 6 F guiding catheters, made of nylon with mesh as support, hydrophilic coating, total length of 145 cm, fastening steel stylet and 25 cm t

Value

MKD Not specified

Guiding catheter Extension, "rapid exchange", compatible with 6 F guiding catheters, made of nylon with mesh as support, hydrophilic coating, total length of 145 cm, fastening steel stylet and 25 cm t Guiding catheter Extension, "rapid exchange", compatible with 6 F guiding catheters, made of nylon with mesh as support, hydrophilic coating, total length of 145 cm, fastening steel stylet and 25 cm tube with an inner diameter of 0.057 inches, with RTG visible markers at the ends of the tube, soft atraumatic tip.

Coronary microcatheter with hydrophilic coating, from 130cm to 150cm length range, distal outer diameter of 1.8 Fr, proximal outer diameter 2.6 Fr. max., compatible with 0.014 inch wire

Value

MKD Not specified

Coronary microcatheter with hydrophilic coating, from 130cm to 150cm length range, distal outer diameter of 1.8 Fr, proximal outer diameter 2.6 Fr. max., compatible with 0.014 inch wire Coronary microcatheter with hydrophilic coating, from 130cm to 150cm length range, distal outer diameter of 1.8 Fr, proximal outer diameter 2.6 Fr. max., compatible with 0.014 inch wire

Peripheral support catheter with hydrophilic coating of distal 40 cm, with steel mesh in the wall, three RTG visible markers on the tip. Conical tip that is straight in shape or curved at an angle, ca

Value

MKD Not specified

Peripheral support catheter with hydrophilic coating of distal 40 cm, with steel mesh in the wall, three RTG visible markers on the tip. Conical tip that is straight in shape or curved at an angle, ca Peripheral support catheter with hydrophilic coating of distal 40 cm, with steel mesh in the wall, three RTG visible markers on the tip. Conical tip that is straight in shape or curved at an angle, catheter with diameter of 4 French, length from 65 to 150 cm, compatible with 0.035 inch wire

Hydrophilic catheter for Thrombocytopenia in coronary arteries, on the principle of vacuum 6 and 7 F, length up to 140 cm, compatible with 0.014" wire, fastening steel stylet, in a set with two vacuum

Value

MKD Not specified

Hydrophilic catheter for Thrombocytopenia in coronary arteries, on the principle of vacuum 6 and 7 F, length up to 140 cm, compatible with 0.014" wire, fastening steel stylet, in a set with two vacuum Hydrophilic catheter for Thrombocytopenia in coronary arteries, on the principle of vacuum 6 and 7 F, length up to 140 cm, compatible with 0.014" wire, fastening steel stylet, in a set with two vacuum syringes and filter baskets.

Peripheral catheter, for support with hydrophilic coating of the distal 40 cm, with steel mesh in the wall, 4 RTG visible markers on tip on each 5 cm. Support in interventions on the arteries below th

Value

MKD Not specified

Peripheral catheter, for support with hydrophilic coating of the distal 40 cm, with steel mesh in the wall, 4 RTG visible markers on tip on each 5 cm. Support in interventions on the arteries below th Peripheral catheter, for support with hydrophilic coating of the distal 40 cm, with steel mesh in the wall, 4 RTG visible markers on tip on each 5 cm. Support in interventions on the arteries below the knee with a 4 French guiding introducer. Conical tip that is straight in shape or curved at an angle, the catheter with a diameter of 2.3 French, length from 65 to 150 cm, compatible with 0.014 inch wire

Balloon catheter for valvuloplasty, with diameter of 18mm to 30mm and length 30 to 60 mm.

Value

MKD Not specified

Balloon catheter for valvuloplasty, with diameter of 18mm to 30mm and length 30 to 60 mm. Balloon catheter for valvuloplasty, with diameter of 18mm to 30mm and length 30 to 60 mm.

Coronary Balloon Dilatation Catheters, semicompliant, with a low profile at the tip of 0.41 mm or 0.016 inches, for passage through stenoses, hydrophilic coating, compatible with 5 French guiding cath

Value

MKD Not specified

Coronary Balloon Dilatation Catheters, semicompliant, with a low profile at the tip of 0.41 mm or 0.016 inches, for passage through stenoses, hydrophilic coating, compatible with 5 French guiding cath Coronary Balloon Dilatation Catheters, semicompliant, with a low profile at the tip of 0.41 mm or 0.016 inches, for passage through stenoses, hydrophilic coating, compatible with 5 French guiding catheter, Rx and OTW options, compatible with 0.014 inch wire. Diameter range from 1.5 to 4 mm, and balloon lengths from 6 to 30 mm. Compatible for kissing technique with simultaneous passing of two balloons in 6 French catheter

Non-deformable, NC (non-compliant) coronary balloon catheters intended for predilatation of hard calcified coronary lesions and occlusions and for post-dilatation in the stent. Compatible with 0.014 i

Value

MKD Not specified

Non-deformable, NC (non-compliant) coronary balloon catheters intended for predilatation of hard calcified coronary lesions and occlusions and for post-dilatation in the stent. Compatible with 0.014 i Non-deformable, NC (non-compliant) coronary balloon catheters intended for predilatation of hard calcified coronary lesions and occlusions and for post-dilatation in the stent. Compatible with 0.014 inch wire. Diameter in the range of 1.5 to 5 mm, and lengths in the range of 6 to 25 mm. Rx and OTW wire placement, low pass profile of 0.026 inches. Compatible for kissing technique with simultaneous passing of two balloons in 6 French catheter

Coronary balloon catheters - NC (Non-compliant) for predilatation of large coronary arteries with hard calcified lesions and occlusions and for post-dilatation in the LM stent. Compatible with 0.014 i

Value

MKD Not specified

Coronary balloon catheters - NC (Non-compliant) for predilatation of large coronary arteries with hard calcified lesions and occlusions and for post-dilatation in the LM stent. Compatible with 0.014 i Coronary balloon catheters - NC (Non-compliant) for predilatation of large coronary arteries with hard calcified lesions and occlusions and for post-dilatation in the LM stent. Compatible with 0.014 inch wire. Diameter in the range of 5.5 and 6 mm, and lengths in the range of 8 to 20 mm. Rx and OTW wire placement, low pass profile of 0.017 inches or 0.43 mm.

Coronary Balloon Catheter, coated with PacTHaxel medicine on BTHC carrier, for dilatation of in-stent restenoses, compatible with 5 French guiding catheter and 0.014 inch wire, Rx. Diameter range from

Value

MKD Not specified

Coronary Balloon Catheter, coated with PacTHaxel medicine on BTHC carrier, for dilatation of in-stent restenoses, compatible with 5 French guiding catheter and 0.014 inch wire, Rx. Diameter range from Coronary Balloon Catheter, coated with PacTHaxel medicine on BTHC carrier, for dilatation of in-stent restenoses, compatible with 5 French guiding catheter and 0.014 inch wire, Rx. Diameter range from 2.0 to 4 mm, and balloon lengths from 10 to 30 mm.

Balloon catheters for peripheral arterial and carotid dilatation, RX (rapid exchange) compatible with 0.014" wire, diameter range from 4.0 to 7.0 mm, lengths from 15 to 40 mm. Shaft length from 80 to

Value

MKD Not specified

Balloon catheters for peripheral arterial and carotid dilatation, RX (rapid exchange) compatible with 0.014" wire, diameter range from 4.0 to 7.0 mm, lengths from 15 to 40 mm. Shaft length from 80 to Balloon catheters for peripheral arterial and carotid dilatation, RX (rapid exchange) compatible with 0.014" wire, diameter range from 4.0 to 7.0 mm, lengths from 15 to 40 mm. Shaft length from 80 to 135 cm. Properties of the material to be fast inflation and deflation and ability for quick removal from the dilatation site. Compatible with 6 French guiding catheter.

Balloon catheters for peripheral arterial dilatation, arteries below the knee, compatible with 0.014" wire, diameter range from 1.5 to 4.0 mm, lengths from 20 to 220 mm. Shaft length from 90 to 150 cm

Value

MKD Not specified

Balloon catheters for peripheral arterial dilatation, arteries below the knee, compatible with 0.014" wire, diameter range from 1.5 to 4.0 mm, lengths from 20 to 220 mm. Shaft length from 90 to 150 cm Balloon catheters for peripheral arterial dilatation, arteries below the knee, compatible with 0.014" wire, diameter range from 1.5 to 4.0 mm, lengths from 20 to 220 mm. Shaft length from 90 to 150 cm. Hydrophilic coating to the balloon, hydrophobic to the shaft. Compatible with 4 French guiding introducer.

Balloon catheter for peripheral arteries compatible with 0.035" guiding wire, OTW system, with balloon diameter from 3.0 mm to 10.0 mm, length of the balloon 20-200 mm, compatible with 5 and 6 F guidi

Value

MKD Not specified

Balloon catheter for peripheral arteries compatible with 0.035" guiding wire, OTW system, with balloon diameter from 3.0 mm to 10.0 mm, length of the balloon 20-200 mm, compatible with 5 and 6 F guidi Balloon catheter for peripheral arteries compatible with 0.035" guiding wire, OTW system, with balloon diameter from 3.0 mm to 10.0 mm, length of the balloon 20-200 mm, compatible with 5 and 6 F guiding introducer, catheter length from 80 to 135 cm, hydrophilic coating

Balloon catheter for peripheral arteries compatible with 0.035" guiding wire, OTW system, with balloon diameter from 3.0 mm to 14.0 mm, length of the balloon 20-250 mm, compatible with 5 and 7 F guidi

Value

MKD Not specified

Balloon catheter for peripheral arteries compatible with 0.035" guiding wire, OTW system, with balloon diameter from 3.0 mm to 14.0 mm, length of the balloon 20-250 mm, compatible with 5 and 7 F guidi Balloon catheter for peripheral arteries compatible with 0.035" guiding wire, OTW system, with balloon diameter from 3.0 mm to 14.0 mm, length of the balloon 20-250 mm, compatible with 5 and 7 F guiding introducer, catheter length from 80 to at least 130 cm, hydrophobic coating

Balloon catheter for peripheral arteries, OTW, coated with cytostatics, coated with Paclitaxel medicine on BTHC carrier, compatible with 0.018" guiding wire, with balloon diameters from 2.0 mm to 7.0

Value

MKD Not specified

Balloon catheter for peripheral arteries, OTW, coated with cytostatics, coated with Paclitaxel medicine on BTHC carrier, compatible with 0.018" guiding wire, with balloon diameters from 2.0 mm to 7.0 Balloon catheter for peripheral arteries, OTW, coated with cytostatics, coated with Paclitaxel medicine on BTHC carrier, compatible with 0.018" guiding wire, with balloon diameters from 2.0 mm to 7.0 mm and with 40-120 mm length of the balloon, with catheter length 90,130 and 150 cm, compatible with 4 and 5 F introducer.

Balloon catheter for peripheral arteries, OTW, consisting of a balloon and a nitinol cage, for controlled PTA. The balloon to have diameters in the range of 2.5 to 6 mm and length from 40 to 120 mm. C

Value

MKD Not specified

Balloon catheter for peripheral arteries, OTW, consisting of a balloon and a nitinol cage, for controlled PTA. The balloon to have diameters in the range of 2.5 to 6 mm and length from 40 to 120 mm. C Balloon catheter for peripheral arteries, OTW, consisting of a balloon and a nitinol cage, for controlled PTA. The balloon to have diameters in the range of 2.5 to 6 mm and length from 40 to 120 mm. Compatible with 0.014 and 0.018 wire and with 5 and 6 French guiding introducer.

Radial band for hemostasis after radial access, with visibility at the puncture site and selective compression of the radial artery, on the principle of inflation in set with a 25 ml syringe, adaptabl

Value

MKD Not specified

Radial band for hemostasis after radial access, with visibility at the puncture site and selective compression of the radial artery, on the principle of inflation in set with a 25 ml syringe, adaptabl Radial band for hemostasis after radial access, with visibility at the puncture site and selective compression of the radial artery, on the principle of inflation in set with a 25 ml syringe, adaptable size and choice of dimensions.

Vascular closure system with collagen and resorptive thread, in set with introducer and guiding wire of 70 cm, size from 6 to 8 French for transformal haemostasis

Value

MKD Not specified

Vascular closure system with collagen and resorptive thread, in set with introducer and guiding wire of 70 cm, size from 6 to 8 French for transformal haemostasis Vascular closure system with collagen and resorptive thread, in set with introducer and guiding wire of 70 cm, size from 6 to 8 French for transformal haemostasis

Thermodulation catheter set for jugular and femoral application with a diameter of 7 French. The set should contain: proximal lumen port 29 cm, catheter with length of 110 cm, thermodulation catheter

Value

MKD Not specified

Thermodulation catheter set for jugular and femoral application with a diameter of 7 French. The set should contain: proximal lumen port 29 cm, catheter with length of 110 cm, thermodulation catheter Thermodulation catheter set for jugular and femoral application with a diameter of 7 French. The set should contain: proximal lumen port 29 cm, catheter with length of 110 cm, thermodulation catheter with balloon Swan-ganz catheter maximum 1.5 cm and inflation catheter with diameter of 12 mm (with allowed deviation of +/- 5 %), control syringe, extension lines, 4 channels, long distal lumen, clear color code and labeled extension lines, with sterile full-length protection and an integrated rinsing/balloon test chamber.

Percutaneous closure system with suture of the punctured artery or vein, after completion of procedures with a large diameter of up to 21 French for arterial and 24 French for venous blood vessel. Com

Value

MKD Not specified

Percutaneous closure system with suture of the punctured artery or vein, after completion of procedures with a large diameter of up to 21 French for arterial and 24 French for venous blood vessel. Com Percutaneous closure system with suture of the punctured artery or vein, after completion of procedures with a large diameter of up to 21 French for arterial and 24 French for venous blood vessel. Compatible and recommended for transfemoral hemostasis after TAVI and related procedures.

Set for interventions consisting of a Balloon Pump with ergonomic holder, working pressure of 30 atm, dilatation pressure control mechanism, ipsilon (Y) connector, input pin, torker

Value

MKD Not specified

Set for interventions consisting of a Balloon Pump with ergonomic holder, working pressure of 30 atm, dilatation pressure control mechanism, ipsilon (Y) connector, input pin, torker Set for interventions consisting of a Balloon Pump with ergonomic holder, working pressure of 30 atm, dilatation pressure control mechanism, ipsilon (Y) connector, input pin, torker

High pressure hose of min 84 Bar (1200 psi) intended for angiography with an injector with a rotating m/f adapter, made of transparent polyurethane with a minimum length of 100 cm.

Value

MKD Not specified

High pressure hose of min 84 Bar (1200 psi) intended for angiography with an injector with a rotating m/f adapter, made of transparent polyurethane with a minimum length of 100 cm. High pressure hose of min 84 Bar (1200 psi) intended for angiography with an injector with a rotating m/f adapter, made of transparent polyurethane with a minimum length of 100 cm.

Central venous pressure set, two-lumen 7F polyurethane catheter with soft atraumatic tip, lumen size 16G/16G, outer diameter of 2.5 mm and length of 20 cm, transparent additional extension with side

Value

MKD Not specified

Central venous pressure set, two-lumen 7F polyurethane catheter with soft atraumatic tip, lumen size 16G/16G, outer diameter of 2.5 mm and length of 20 cm, transparent additional extension with side Central venous pressure set, two-lumen 7F polyurethane catheter with soft atraumatic tip, lumen size 16G/16G, outer diameter of 2.5 mm and length of 20 cm, transparent additional extension with side clamp, flexible guiding wire with steel J-tip with dimensions of 0.9 mm x 50 cm, bending resistant, introducer needle for Sellinger 18G with length of 70 mm, radiopaque in length, integrated movable fixation

SIMILAR TENDERS

Norway : Lillestrøm - Cleaning and polishing products

Norway

Value: 71.0 million Norwegian Krone

United Kingdom : Normanton - Personal care products

United Kingdom of Great Britain and Northern Ireland

Value: 395.2 million Pound Sterling

Norway : Oslo - Scanners

Norway

Value: 1.5 million Norwegian Krone

Germany : Berlin - Personal care products

Germany

Value: Not specified

Malta : Floriana - Medicinal products used in diabetes

Malta

Value: Not specified

United Kingdom : Edinburgh - Orthopaedic implants

United Kingdom of Great Britain and Northern Ireland

Value: 15.0 million Pound Sterling

United Kingdom : Salford - Computer equipment and supplies

United Kingdom of Great Britain and Northern Ireland

Value: 1.0 billion Pound Sterling